LU Series
Clamp-onSplit DesignWide Range
Ultrasonic Flow Meter

LU Series

LU Series clamp-on ultrasonic flow meter features ambient temperature split design. The sensor clamps onto the outside of the pipe, requiring no pipe modification. Simple installation with four screws, no specialized knowledge required. No moving parts, zero pressure loss, can be installed without shutting down production. Widely used in pharmaceutical blending, beverage industry, fine chemical, cleaning equipment and other fields.

Key Takeaways

  • High-precision measurement & control, professional Liquid Flow Measurement & Control solution
  • MEMS thermal flow sensor chip technology for fast response
  • Supports RS485/Modbus/4-20mA multiple communication protocols
  • Widely used in semiconductor, new energy, biopharma industries
  • Professional selection support and complete after-sales service

Key Specifications

Measurement PrincipleUltrasonic transit-time method
InstallationClamp-on split type
Accuracy±2.0%
Flow Velocity Range0.1-5.0 m/s
Pipe DiameterDN6-DN100
Media Temperature-10°C~60°C
Email Us

Model Specifications

基本参数
测量原理超声波时差法
安装方式外卡分体式,传感器与主机分离
精度±2.0%(流速0.3-5.0m/s)
重复性±0.5%
流速范围0.1-5.0 m/s(可测范围) 0.3-5.0 m/s(准确度范围)
流量单位m³/h、L/min、ml/min、GPM、L/h
管道规格
管径范围DN6-DN100(外径Φ9.53-Φ110mm)
管道材质金属管:不锈钢管、碳钢管、铜管 塑料管:PVC、CPVC、PPR、PPH、PFA、PU、HDPE等
壁厚范围1-10mm
流量范围(按管径)
DN6 (Φ9.53)0.44-30 L/min
DN10 (Φ12.7)0.92-70 L/min
DN15 (Φ15)0.2-20 L/min
DN20 (Φ20)0.57-50 L/min
DN25 (Φ25)1.36-150 L/min
DN32 (Φ32)2.71-200 L/min
DN40 (Φ40)4.24-330 L/min
DN50 (Φ50)6.8-460 L/min
DN65 (Φ63)9.54-700 L/min
DN80 (Φ75)14.8-1030 L/min
DN100 (Φ110)36.5-2170 L/min
可测介质
介质类型水、纯水、超纯水、各种酸、碱、有机液体、化学溶剂、酒精、饮料等
介质要求洁净流体,不会因流动产生气泡,压力保持0.3MPa以上
适测粘度<300 CST (mm²/s)
电气参数
供电电源DC 12-36V
功耗≤2W
输出信号4-20mA、RS485(Modbus-RTU)、脉冲输出
通讯协议Modbus-RTU
显示与操作
显示屏LCD液晶显示
显示内容瞬时流量、瞬时流速、净累积量、单次累积量
操作方式4个轻触按键
环境参数
介质温度-10°C~60°C
环境温度-10°C~50°C
环境湿度0%-95%RH,无凝露
防护等级IP65
机械参数
主机材质ABS材料
传感器材质工程塑料
电缆长度2.0米(可加长至20米)
净重约1.0kg

LU300B系列采用外卡式安装,传感器卡在管道外部,无需破管、无需停产。

四颗螺丝固定安装,操作简单,不需要专业知识。

非接触式测量,无可动部件,无压力损失。

适用于金属管和塑料管,一台流量计可测量多种材质管道。

广泛应用于医药配比、饮料行业、精细化工、清洗设备等领域。

Key Features

Clamp-on Mount

Sensor clamps on pipe outside

Easy Install

Four screws mounting

Zero Pressure Loss

No moving parts

Wide Range

DN6-DN100 available

Multi-material

Metal/Plastic pipe compatible

Split Design

Sensor and host separated

Applications

AI Data Center
Hydrogen Energy
Semiconductor
Laboratory
Food & Pharma
Surface Treatment

AI Data Center Liquid Cooling Solutions

Precision liquid flow measurement & control for AI computing infrastructure

Industry Background

With the rapid development of AI large models, GPU clusters, and high-density computing, single-chip power consumption has exceeded 1000W. Traditional air cooling can no longer meet the demand. Liquid cooling, with its efficient heat transfer capability, has become the mainstream solution for AI data centers and supercomputing centers. Precise coolant flow measurement and control directly determine cooling efficiency and equipment safety.

Key Challenges

  • GPU/CPU chip temperature fluctuation must be controlled within ±1°C
  • Coolant flow requires precise distribution to avoid hotspots
  • CDU (Coolant Distribution Unit) needs real-time multi-channel monitoring
  • Leak detection requires millisecond response to protect expensive equipment
  • Systems must operate 24/7 with high reliability

GASKITO Liquid Cooling Flow Solutions

Precision Flow Measurement

Ultrasonic/electromagnetic flow meters with ±0.5% accuracy, real-time coolant flow monitoring ensuring precise cooling delivery to each rack

Fast Response Control

<1 second response time, dynamic flow adjustment with control valves, chip temperature fluctuation controlled within ±0.5°C

Real-time Leak Detection

Ultra-low flow detection capability, minimum measurable 0.001m/s, millisecond leak response triggering immediate protection

Multi-channel Integration

RS485/Modbus communication support, monitoring dozens of CDU branches simultaneously, unified DCIM system integration

Cold Plate Cooling

Chip-level cold plate flow monitoring

Immersion Cooling

Immersion tank coolant circulation

CDU Units

Primary/secondary flow ratio control

Outdoor Cooling

Dry cooler/cooling tower monitoring

Expert Selection Support:Customized solutions from single flow meters to complete liquid cooling monitoring systems

Downloads

Need More Information?

Contact our professional team for detailed product selection and technical support

Email Us

Frequently Asked Questions

Disclaimer: The content on this page is for reference only and does not constitute any offer or commitment. Product specifications and parameters are subject to change without notice. Please refer to the actual product manual.

Last Updated: 2026-08-07(Content updated regularly)