FCS / SYSTEMS & SOLUTIONS

Product appearance varies by configuration.
Fluid Control Solutions (FCS)
QT200 Series Gas Mixer
The QT200 Series gas mixer is designed to supply shielding gas to one or two welding machines. It uses mass flow measurement in place of conventional variable-area flowmeters. Inlet and outlet pressure sensors support real-time monitoring, while flow limit alarms, switching alarm outputs, and data logging support process analysis and traceability.
- Blend Accuracy
- ±2%
- Inlet Pressure
- 0.4~1 MPa
- Maximum Flow
- 25~200 L/min
- Dimensions
- 340 mm × 185 mm × 290 mm
Configuration and suitability confirmed for your application.
Model Specifications
| QT200-50-C50Ar | Maximum Flow (L/min): 50 Blend Range: 0~50% CO₂, balance argon Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-100-C50Ar | Maximum Flow (L/min): 100 Blend Range: 0~50% CO₂, balance argon Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-50-C50N | Maximum Flow (L/min): 50 Blend Range: 0~50% CO₂, balance nitrogen Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-100-C50N | Maximum Flow (L/min): 100 Blend Range: 0~50% CO₂, balance nitrogen Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-100-Ar20He | Maximum Flow (L/min): 100 Blend Range: 0~20% argon, balance helium Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-200-Ar20He | Maximum Flow (L/min): 200 Blend Range: 0~20% argon, balance helium Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-25-O2Ar | Maximum Flow (L/min): 25 Blend Range: 0~2% oxygen, balance argon Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-25-H10Ar | Maximum Flow (L/min): 25 Blend Range: 0~10% hydrogen, balance argon Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
| QT200-30-O20Ar | Maximum Flow (L/min): 30 Blend Range: 0~20% oxygen, balance argon Inlet Connection: 1/4"NPT(F) Outlet Connection: 1/4"NPT(F) |
Performance Specifications
| Blend Accuracy | ±2% |
| Inlet Pressure Range | 0.4~1 MPa |
| Dimensions | 340 mm × 185 mm × 290 mm |
| Weight | 7.2 kg |
| Pressure Monitoring | Real-time inlet and outlet pressure measurement |
| Flow Monitoring | Mass flow measurement |
Features
| Data Storage | Flow and pressure data logging and export |
| Alarm Function | High/low flow alarms with switching alarm outputs |
| Supported Equipment | 1–2 welding machines |
Measurement conditions & notes
- Uses mass flow measurement instead of conventional variable-area flowmeters; specified blend accuracy is ±2%.
- Inlet and outlet pressure sensors support real-time pressure monitoring.
- High/low flow alarms provide switching signals for automation systems.
- Flow and pressure data can be stored and exported for traceability and process analysis.
- 9 models cover gas combinations including CO₂+Ar, CO₂+N₂, Ar+He, O₂+Ar, and H₂+Ar.
- Designed for shielding gas supply to 1–2 welding machines.
- Compact design with straightforward installation and operation.
Confirm fluid compatibility, materials, connections, and available configuration with our team before ordering.