FLOW MEASUREMENT & CONTROLservice@gaskito.com
LIQUID FLOWLU300B Series

Product appearance varies by configuration.

Liquid Flow Measurement & Control

LU300B Series

The LU300B Series clamp-on ultrasonic flow meter uses separate sensor and electronics units. The sensor mounts on the outside of the pipe, enabling installation without pipe modification or a production shutdown. With no moving parts in the flow path, it adds no pressure drop. Applications include pharmaceutical blending, beverage production, fine chemical processing, and cleaning equipment.

Measurement Principle
Ultrasonic transit-time method
Mounting
Clamp-on split type
Accuracy
±2.0% at 0.3–5.0 m/s
Flow Velocity Range
0.1-5.0 m/s
Request a quote

Configuration and suitability confirmed for your application.

Basic Parameters

Measurement PrincipleUltrasonic transit-time method
MountingSeparate clamp-on sensor and electronics
Accuracy±2.0% (velocity 0.3–5.0 m/s)
Repeatability±0.5%
Flow Velocity Range0.1–5.0 m/s (measurement range) 0.3–5.0 m/s (specified accuracy range)
Flow Unitsm³/h, L/min, ml/min, GPM, L/h

Pipe Specifications

Pipe DiameterDN6–DN100 (outside diameter Φ9.53–Φ110 mm)
Pipe MaterialsMetal: stainless steel, carbon steel, copper Plastic: PVC, CPVC, PPR, PPH, PFA, PU, HDPE, etc.
Wall Thickness Range1-10mm

Flow Range by Pipe Size

DN6 (Φ9.53)0.44-30 L/min
DN10 (Φ12.7)0.92-70 L/min
DN15 (Φ15)0.2-20 L/min
DN20 (Φ20)0.57-50 L/min
DN25 (Φ25)1.36-150 L/min
DN32 (Φ32)2.71-200 L/min
DN40 (Φ40)4.24-330 L/min
DN50 (Φ50)6.8-460 L/min
DN65 (Φ63)9.54-700 L/min
DN80 (Φ75)14.8-1030 L/min
DN100 (Φ110)36.5-2170 L/min

Compatible Fluids

Media TypeWater, purified and ultrapure water, compatible acids, alkalis, organic liquids, chemical solvents, alcohol, and beverages
Media RequirementClean fluid without flow-induced bubbles; maintain pressure above 0.3 MPa
Supported Viscosity<300 CST (mm²/s)

Electrical Parameters

Power SupplyDC 12-36V
Power Consumption≤2W
Output Signals4–20 mA, RS485 (Modbus RTU), pulse output
Communication ProtocolModbus-RTU

Display & Operation

DisplayLCD
Display InformationInstantaneous flow, velocity, net total, and batch total
Operation4 tactile buttons

Environmental Specifications

Media Temperature-10°C~60°C
Ambient Temperature-10°C~50°C
Ambient Humidity0%–95% RH, noncondensing
ProtectionIP65

Mechanical Parameters

Electronics Housing MaterialABS
Sensor MaterialEngineering plastic
Cable Length2.0 m (extendable to 20 m)
Net WeightApproximately 1.0 kg

Measurement conditions & notes

  1. The LU300B sensor clamps onto the outside of the pipe without cutting the pipe or stopping production.
  2. Four screws secure the sensor for straightforward installation.
  3. Non-contact measurement has no moving parts in the flow path and adds no pressure drop.
  4. Supports multiple compatible metal and plastic pipe materials.
  5. Applications include pharmaceutical blending, beverage production, fine chemical processing, and cleaning equipment.

Confirm fluid compatibility, materials, connections, and available configuration with our team before ordering.