FLOW MEASUREMENT & CONTROLservice@gaskito.com
LIQUID FLOWLU300A Series

Product appearance varies by configuration.

Liquid Flow Measurement & Control

LU300A Series

The LU300A Series combines the sensor and electronics in a compact, integrated clamp-on ultrasonic flow meter. It mounts on the outside of the pipe without changing the piping or interrupting production. The non-invasive design has no moving parts in the flow path and adds no pressure drop.

Measurement Principle
Ultrasonic transit-time method
Mounting
Integrated clamp-on design
Accuracy
±2.0% at 0.3–5.0 m/s
Flow Velocity Range
0.1-5.0 m/s
Request a quote

Configuration and suitability confirmed for your application.

Basic Parameters

Measurement PrincipleUltrasonic transit-time method
MountingIntegrated clamp-on sensor and electronics
Accuracy±2.0% (velocity 0.3–5.0 m/s)
Linearity±2.0% (velocity 0.3–5.0 m/s)
Repeatability0.8%
Flow Velocity Range0.1–5.0 m/s (measurement range) 0.3–5.0 m/s (specified accuracy range)
Response Time500ms

Pipe Specifications

Pipe DiameterDN6–DN100 (outside diameter Φ9.53–Φ110 mm)
Pipe MaterialsMetal: stainless steel, carbon steel, copper Plastic: PVC, CPVC, PPR, PPH, PFA, PU, HDPE, etc.
Wall Thickness Range1-10mm

Flow Range by Pipe Size

DN6 (Φ9.53)0.2-20 L/min
DN8 (Φ12.7)0.44-30 L/min
DN10 (Φ15)0.57-50 L/min
DN15 (Φ20)0.92-70 L/min
DN20 (Φ25)1.36-150 L/min
DN25 (Φ32)2.71-200 L/min
DN32 (Φ40)4.24-330 L/min
DN40 (Φ50)6.8-460 L/min
DN50 (Φ63)9.54-700 L/min
DN65 (Φ75)14.8-1030 L/min
DN80 (Φ90)21.8-1360 L/min
DN100 (Φ110)36.5-2170 L/min

Compatible Fluids

Media TypeWater, purified and ultrapure water, compatible acids, alkalis, organic liquids, chemical solvents, alcohol, and beverages
Media RequirementClean fluid without flow-induced bubbles; maintain pressure above 0.3 MPa
Supported Viscosity<300 CST (mm²/s)

Electrical Parameters

Power SupplyDC 24V @ 3W
Analog Output4–20 mA, maximum load 600 Ω
Communication InterfaceRS485 with Modbus RTU
Alarm OutputOCT high/low limit alarm outputs and pulse output (optional)
Relay Output30 V DC @ 1 A (optional), switching frequency <2 Hz

Display & Operation

Display1.3-inch 128×64 OLED with reversible orientation
Menu LanguagesEnglish
Display Unitsm³/h, L/min, GPM, L/h
Displayed DataInstantaneous flow, velocity, net total, batch total, and daily/monthly/yearly totals
Totalizer7-digit flow totalizer
Stored Totals10 years, 64 months, 64 days
Operating Buttons4 tactile buttons
Real-Time Clock BatteryCR1220

Environmental Specifications

Media Temperature-10°C~50°C
Ambient Temperature-10°C~50°C
Ambient Humidity0%–95% RH, noncondensing
ProtectionIP54/IP65

Mechanical Parameters

Mounting MethodIntegrated clamp-on design secured with screws
Wetted PartsNon-contact measurement
Cable Length2.0 m (extendable to 20 m)

Measurement conditions & notes

  1. The LU300A integrates the sensor and electronics in a compact unit.
  2. The sensor clamps onto the outside of the pipe without pipe cutting or a production shutdown.
  3. Four screws secure the sensor for straightforward installation.
  4. Non-contact measurement has no moving parts in the flow path and adds no pressure drop.
  5. Supports multiple compatible metal and plastic pipe materials.
  6. Applications include semiconductors, pharmaceuticals, medical equipment, chemical processing, cleaning, and food and beverage production.

Confirm fluid compatibility, materials, connections, and available configuration with our team before ordering.