FLOW MEASUREMENT & CONTROLservice@gaskito.com
MFM / GAS FLOWKM1000 Series

Product appearance varies by configuration.

Mass Flow Meter (MFM)

KM1000 Series

The KM1000 Series gas mass flow meter uses a solid-state sensor for stable measurement with a linear output. Analog and digital output options are available. Applications include photovoltaic equipment, vacuum pumps, analytical instruments, spectrometers, and medical equipment. See the datasheet for response time, flow range, and shock resistance.

Range
300~1000 SLM
Accuracy
≤±2.5%F.S.
Resolution
0.1%F.S.
Repeatability
≤1.0%F.S.
Request a quote

Configuration and suitability confirmed for your application.

Basic Parameters

Measurement Range300~1000 SLM (selectable ranges)
Accuracy≤±2.5%F.S.
Resolution0.1%F.S.
Repeatability≤1.0%F.S.
Zero Drift≤0.5%F.S.
Response Time≤10ms
Maximum Pressure1 MPa (custom options available)

Electrical Parameters

Working Voltage9~24 V DC (current-output version: 24 V DC)
Working Current<30mA
Output Impedance>30kΩ

Communication Interface

CommunicationRS485 (MODBUS)
Analog Voltage Output1~5 V / 0.5~4.5 V / 0~5 V (custom options available)
Analog Current Output4~20mA
Alarm OutputPNP/NPN (custom options available)

Displayed Parameters

DisplayInstantaneous flow / totalized flow (SLM)

Environmental Conditions

Operating Temperature0~50℃
Storage Temperature-20~70℃

Mechanical Parameters

Connector TypeG1/2 (custom options available)

Measurement conditions & notes

  1. The KM1000 uses a solid-state sensor without surface cavities or a fragile diaphragm, designed to resist blockage and pressure shocks.
  2. Linear output, low zero drift, and stable long-term measurement.
  3. Applications include photovoltaic equipment, vacuum pumps, analytical instruments, spectrometers, and medical equipment.

Confirm fluid compatibility, materials, connections, and available configuration with our team before ordering.